CJX9 air conditioner contactor
CJX9 air conditioner definite purpose magnetic contactor
This series contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated working voltage up to 600V and rated working current up to 60A, used to close or and to switch off the line. It complies to IEC947-4-1 .Straight-through wiring, replaces 1.5 pole devices used primarily in residential central air conditioning.Replaces many type 117 contactors used by OEM’sUniversal style mounting brackest fits existing mounting holes Screw terminals and quick connect terminals for easy installation.
Coil rating | 1Pole contactors | 2 pole contacts | ||||||
Nominal coil voltage | 24 | 120 | 208/240 | 277 | 24 | 120 | 208/240 | 277 |
Nominal coil resistance Ohms | 18 | 420 | 1800 | 2500 | 11 | 237 | 1000 | 1600 |
Maximum pick up voltage | 18 | 88 | 177 | 221 | 18 | 88 | 177 | 221 |
Maximum drop out voltage | 6-15 | 20-70 | 40-140 | 50-165 | 6-15 | 20-70 | 40-140 | 50-165 |
Nominal rush Va@50Hz | 31 | 31 | 31 | 31 | 33 | 33 | 33 | 33 |
Nominal rush Va@60Hz | 28 | 28 | 28 | 28 | 30 | 30 | 30 | 30 |
Nominal rush Va@50Hz | 6 | 6 | 6 | 6 | 8 | 8 | 8 | 8 |
Nominal rush Va@60Hz | 5 | 5 | 5 | 5 | 6.5 | 6.5 | 6.5 | 6.5 |
Maximum coil voltage | 30 | 132 | 264 | 300 | 30 | 132 | 132 | 300 |
Coil rating | 3Pole contactors | 4 pole contacts | ||||||
Nominal coil voltage | 24 | 120 | 208/240 | 277 | 24 | 120 | 208/240 | 277 |
Nominal coil resistance Ohms | 7 | 180 | 720 | 900 | 6 | 150 | 600 | 750 |
Maximum pick up voltage | 18 | 88 | 177 | 220 | 18 | 88 | 177 | 220 |
Maximum drop out voltage | 6-15 | 20-70 | 40-140 | 50-165 | 6-15 | 20-70 | 40-140 | 65-185 |
Nominal rush Va@50Hz | 65 | 65 | 65 | 65 | 62 | 62 | 62 | 62 |
Nominal rush Va@60Hz | 60 | 60 | 60 | 60 | 59 | 59 | 59 | 59 |
Nominal rush Va@50Hz | 7.5 | 7.5 | 7.5 | 7.5 | 9 | 9 | 9 | 9 |
Nominal rush Va@60Hz | 6 | 6 | 6 | 6 | 7 | 7 | 6 | 7 |
Maximum coil voltage | 30 | 132 | 264 | 300 | 30 | 132 | 264 | 300 |